A conference paper published on November 16, 2026, documents how NASA Johnson Space Center conducted a 15-day thermal-vacuum test of Blue Origin’s MK1 lunar lander. The newly published account describes one thermal cycle, four thermal-balance conditions, and two performance tests inside Chamber A in Houston.
The paper, by Ariel Tello of Amentum and Steven Del Papa of NASA Johnson, adds operational detail to a campaign NASA had already announced as complete on May 4. It explains the purpose-built heating equipment, coordination between the facility and vehicle teams, and measurements used to monitor contamination during the test.
The work appears in the Space Simulation Conference proceedings associated with the November 16–19 meeting in Annapolis, Maryland. Its subject is the completed ground-test campaign and the facility preparations that supported it.
Recreating the Thermal Conditions of Spaceflight
Thermal-vacuum testing combines low pressure with controlled heating and cooling. Removing most of the air changes how heat moves around a spacecraft, and the surrounding equipment reproduces selected thermal conditions expected during flight. Engineers then measure the vehicle’s response.
The paper says the MK1 campaign characterized active and passive thermal-control systems and supplied data for checking thermal models. Active systems use powered equipment to regulate temperature. Passive features depend on material properties, insulation, and the way components exchange heat.
A thermal model predicts temperatures and heat flows under specified conditions. Test measurements provide a physical comparison with those predictions. Holding the vehicle at selected thermal-balance conditions allows engineers to examine its response after the relevant temperatures have stabilized.
MK1 is Blue Origin’s uncrewed Blue Moon cargo lander, also known as Endurance. The company’s wider Blue Moon lander family includes the larger MK2 design for human transportation. The conference paper focuses on the MK1 vehicle and its test environment.
NASA’s May test-completion announcement identifies the work as a reimbursable Space Act Agreement activity. That arrangement provided Blue Origin access to NASA’s facility and technical support for its commercially funded demonstration spacecraft.
A Heater Cage With 33 Control Zones
NASA’s Systems Test Branch designed, fabricated, and installed a heater cage around the vehicle. The paper describes multiple heater bars divided among 33 control zones. Each zone could be regulated separately to apply the heating pattern specified for the test.
The Design and Analysis Branch supported the heater layout and the predicted settings. During operations, heater power was increased gradually toward the calculated baseline. After the system stabilized, individual zones were adjusted to reach and maintain the desired temperature profile.
This arrangement allowed the facility team to change heat input around the lander without treating the entire vehicle as one uniformly heated object. The independently controlled zones were part of the equipment used to reproduce the selected flight conditions.
The cage also required structural evaluation in two configurations: inside Chamber A and rolled into the adjoining cleanroom. The analyses covered loads associated with temperature, personnel, assembly, and disassembly. The test equipment had to support both the thermal campaign and the physical work of integrating the spacecraft.
Before vehicle testing, facility readiness work included running the hottest and coldest cases, checking heater operation, and examining the temperature sensors. The subsequent test-readiness review confirmed the completed setup, procedures, material records, and personnel preparation.
Coordinating Facility and Vehicle Operations
NASA’s test directors managed the chamber’s thermal and vacuum conditions and directed the facility team. Blue Origin’s test conductor coordinated the company’s activities, including vehicle operations and the staffing needed for data analysis.
The paper describes communication concentrated through those two roles. This connected changes in the facility environment with actions on the spacecraft. Vehicle functional tests took place throughout the campaign, with the teams coordinating to keep the measurements representative of the intended conditions.
The chamber and cleanroom operated as a connected contamination-control environment. Although designed for ISO Class 7 cleanliness, they were held to an ISO Class 8 requirement for this test. Personnel used protective cleanroom clothing, and the team controlled the introduction of materials that could release particles or vapors.
Contamination matters because material released under vacuum can deposit on nearby surfaces. The paper describes quartz-crystal instruments that monitored deposition by measuring changes in a crystal oscillator as mass accumulated on it.
Three cryogenic quartz-crystal microbalances were controlled at 243 kelvin, or minus 30 degrees Celsius. Two were positioned near the spacecraft and a third was placed at an established chamber location. Their measurements tracked deposition during the campaign.
Checking the Chamber After the Test
Post-test work included inspections and analysis of material collected in the chamber. The team compared control samples with condensate and residue collected after thermal-vacuum operations. Witness samples were also recovered to examine deposited residue and optical properties.
The paper reports propylene glycol among the identified constituents and relates it to a propylene-glycol-and-water mixture used in ground-support equipment for the test. This chemical analysis helped connect a measured chamber residue with a material used during operations.
The authors describe the 15-day campaign as a completed demonstration of Chamber A’s ability to support the vehicle’s test configuration. Post-test contamination assessments documented the chamber’s condition and its return to the baseline needed for subsequent government and commercial testing.